FIBARO Relay Switch 1x2,5kW FGS-212
search
  • FIBARO Relay Switch 1x2,5kW FGS-212
  • FIBARO Relay Switch 1x2,5kW FGS-212
  • FIBARO Relay Switch 1x2,5kW FGS-212
  • FIBARO Relay Switch 1x2,5kW FGS-212
  • FIBARO Relay Switch 1x2,5kW FGS-212

FIBARO Relay Switch 1x2,5kW FGS-212



FGS-212

The FIBARO Relay Switch allows to control loads up to 2.5KW. Relay Switch can switch on or off devices connected to the plugs.

This product is no longer available for sale

The FIBARO Relay Switch allows to control loads up to 2.5KW. Relay Switch can switch on or off devices connected to the plugs. Relay Switch designed to be installed in standard wall switch boxes or anywhere else it’s necessary to operate an electric device of 2500W of power output. The FIBARO Relay Switch is the smallest relay module available on a market, measuring just 20 mm high.

There is no need to wonder whether you forgot to turn TV or lamp in the bedroom off. With a special scene, with only one button you can turn all appliances and lights off when leaving home. It is a simple way to reduce unnecessary energy loss, bring your bills down and take care of the environment.

How often do you look for the TV remote control? With FIBARO System you can just sit on the couch and use your smartphone to control integrated home theater system. Appropriately configured scenes will automatically dim the lights and close the blinds after TV is turned on. Enjoy your movie!

FEATURES :

  • Wireless On/Off control of any appliances
  • Controls light, allows to create different light scenes
  • Fits into standard switch boxes
  • May be used to control heating

TECHNICAL DATAS :

  • Wireless technology: Z-Wave
  • Voltage: 110 - 240V AC or 24 - 60V DC
  • Maximum load : 2500W - 10A (230V AC or 30V DC)
  • Power Consumption: < 0.8W
  • Range: up to 50m (outdoors) and 30m (indoors)
  • Dimensions (LxWxH): 43 x 38 x 20 mm
  • Firmware Versions: v2.1

FGS-212

Data sheet

Type
Micromodule
Functions
Actuator
Technology
Z-Wave
Compatible Fibaro HC2
Oui
Compatible Fibaro HC Lite
Oui
Compatible ZIPABOX
Oui
Compatible eedomus
Oui
Compatible Zibase
Oui
Compatible ZiBASE Pro
Oui
Compatible Vera
Oui
Compatible RFXCOM
Non
Compatible Myfox v1
Non
Compatible Myfox v2
Non
Compatible Piper
Oui
Power Supply
Main power
View the trust certificate
  • For further information on the nature of the review controls, as well as the possibility of contacting the author of the review please consult our Transparency Charter.
  • No inducements have been provided for these reviews
  • Reviews are published and kept for a period of five years
  • Reviews can not be modified: If a customer wishes to modify their review then they can do so by contacting Verified Reviews directly to remove the existing review and publish an amended one
  • The reasons for deletion of reviews are available here.

4.7 /5

Based on 55 customer reviews

  • 1
    0
  • 2
    1
  • 3
    2
  • 4
    12
  • 5
    40
Sort reviews by :

Anonymous customer published the 18/01/2020 following an order made on 16/12/2019

5/5

Bien

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 27/11/2019 following an order made on 01/11/2019

5/5

Article au TOP

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 17/05/2019 following an order made on 29/04/2019

5/5

Non posé à ce jour.

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 07/03/2019 following an order made on 15/02/2019

5/5

livraison rapide conforme à la commande

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 10/01/2019 following an order made on 16/12/2018

4/5

Fonctionne correctement

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 20/12/2018 following an order made on 26/11/2018

5/5

conforme à mes besoins

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 22/11/2018 following an order made on 01/11/2018

5/5

Excellent qualité. Tres bon produit

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 17/05/2018 following an order made on 01/05/2018

5/5

Reconnu de suite et sans aucun problème par ma box eedomus plus

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 09/04/2018 following an order made on 27/03/2018

4/5

pas encore installe

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 13/01/2018 following an order made on 27/12/2017

5/5

Très rapide et conforme

Did you find this helpful? Yes 0 No 0

×

These terminals are intended to be connected to the switch. S1 controls output O1, and S2 controls output O2.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

Yes, you can – the micromodule is voltage free by default.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

No, the micro switch module must be connected to the neutral wire. To control a circuit in which you do not have a neutral wire at the switch, please refer to the dimmer micromodule.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

Yes. In this case, the "I" terminal must be connected to the "+" of the power supply.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

Any voltage up to 230 V AC.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

Check the 3rd association group setting. Make sure it's not empty.

Add your primary Z-Wave controller to this group (try removing it and adding it again).

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. The FIBARO Switch Micromodule has been reset.

After a reset the FIBARO Switch Micromodule will be set to default. To use it, you must again make the inclusion to your Z-Wave controller.

2. Power is off.

The FIBARO Switch Micromodule must be powered by 110-230V AC. Please check your power supply using a voltage tester or multimeter.

3. The FIBARO Switch Micromodule is out of range of the Z-Wave controller.

The FIBARO Switch Micromodule must be within direct range of the Z-Wave controller or within range of another node on the Z-Wave mesh network.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

The FIBARO Switch Micromodule cannot support more than 5 devices per association group.

If you want to control more than 5 devices, please use scenarios.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. The FIBARO Relay Switch is not powered.

The FIBARO Relay Switch must be powered by 110-230V AC. Please check your power supply using a voltage tester or multimeter.

2. The FIBARO Relay Switch has been reset.

After a reset the FIBARO Relay Switch will be set to default. To use it, you must again make the inclusion to your Z-Wave controller.

3. The FIBARO Relay Switch is out of range of the Z-Wave controller.

The FIBARO Relay Switch must be within direct range of the Z-Wave controller or within range of another node on the Z-Wave mesh network.

4. The FIBARO Relay Switch is broken.

Please contact your retailer for information on returning the product and benefiting from the warranty.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. The FIBARO Switch Micromodule is already included in another Z-Wave controller.

 

The FIBARO Switch Micromodule must be deleted using the Z-Wave controller or must be reset.

 

 

 

2. The FIBARO Relay Switch is too far from the Z-Wave controller.

The FIBARO Relay Switch must be within direct range of the Z-Wave controller during the inclusion process.

3. The FIBARO Relay Switch is not powered.

The FIBARO Relay Switch must be powered by 110-230V AC. Please check your power supply using a voltage tester or multimeter.

4. The FIBARO Relay Switch Module has a different frequency (EU, US, or ANZ) than your Z-Wave controller.

The FIBARO Relay Switch must operate on the same Z-Wave frequency (EU, US, or ANZ) as your Z-Wave controller. If you have devices operating on different frequencies, please contact your dealer.

5. The FIBARO Relay Switch is broken.

Please contact your retailer for information on returning the product and benefiting from the warranty.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

You might also like