HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
search
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating
  • HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating

HEATIT CONTROLS - Z-TEMP2 Z-Wave+ thermostat for waterbased heating



HEATIT_4512666
€85.20 Tax included

Heatit Z-Temp2 is a temperature sensor designed for use with waterbased heating systems.

Quantity

 

Security guarantees

 

Shipping Policy

  

Heatit Z-Temp2 is a temperature sensor designed for use with waterbased heating systems. Using it in combination with the Heatit Z-Water regulator allows for an advanced waterbased heating solution that can be managed from a Z-Wave gateway. This is a “wire-free” solution, saving both time and money. All communication between the Heatit Z-Temp2 and the controlled device is 100% wireless. Heatit Z-Temp2 has SmartStart. This feature allows the user to include all devices with SmartStart by scanning the QR codes on the devices. On startup all the devices will automatically be included in the gateway (requires SmartStart compatibility). This saves the installer a lot of work.

Heatit Z-Temp could also be used in situations where a traditional electrical thermostat is not suited. The thermostat may be combined with the Heatit Z-Relay as the actuator installed in a remote location. The Heatit Z-Temp2 is an excellent choice when restoring or remodeling existing buildings, as it is easy to install without any need for wiring.

FEATURES :

  • Z-Wave thermostat for controlling external relay
  • Internal room sensor
  • Humidity sensor
  • Proximity sensor to turn on the display
  • SmartStart
  • Automatic brightness control
  • Firmware updates (OTA)
  • Weekly program/setback via gateway
  • Associations
  • Lock mode/child lock
  • Supports encryption modes S0, S2 Authenticated Class, S2 Unauthenticated Class

TECHNICAL SPECIFICATIONS :

  • Protocol: Z-Wave Plus V2, 868,4MHz
  • Chip: Z-Wave 700 chip
  • Rated voltage: 3 x AA batteries (1,5V)
  • Ambient temperature: 0°C til 60°C
  • Humidity: Max. 85% RH
  • Range RF: Min. 40 meters
  • Hysteresis: 0,3°C to 3,0°C (default 0,5°C)
  • IP Code: IP 21
  • Dimensions: 85 x 85 x 25 mm
  • Approvals: Z-Wave Plus, CE RoHS, 2011/65/EU
HEATIT_4512666

Data sheet

Type
Thermostat
Functions
Humidity
Temperature
Technology
Z-Wave Plus V2
Power Supply
Battery
Thermostat Type
Programmable thermostat
Compatibility
Eedomus
Fibaro HC3
Fibaro HC3 Lite
Homey
Jeedom
Z-Wave specificity
Security S2
SmartStart
View the trust certificate
  • For further information on the nature of the review controls, as well as the possibility of contacting the author of the review please consult our Transparency Charter.
  • No inducements have been provided for these reviews
  • Reviews are published and kept for a period of five years
  • Reviews can not be modified: If a customer wishes to modify their review then they can do so by contacting Verified Reviews directly to remove the existing review and publish an amended one
  • The reasons for deletion of reviews are available here.

3 /5

Based on 1 customer reviews

  • 1
    0
  • 2
    0
  • 3
    1
  • 4
    0
  • 5
    0
Sort reviews by :

Anonymous customer published the 28/10/2020 following an order made on 14/10/2020

3/5

Affichage qui scintille. Intégration non reconnue par jeedom en natif . Qq paramètres inexploité comme la détection de présence. Sinon fait le job

Did you find this helpful? Yes 1 No 0

×

Pressing and holding the bind button for 20 seconds will cause the thermostat to perform a full factory reset. rES will be displayed.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

Please refer to your main controller/gateway manual for how to enter exclusion mode. The device can only be deleted from the network if the main controller is in exclusion mode.

When the main controller/gateway is configured in exclusion mode, press the link button on the thermostat 3 times in a rapid sequence (less than 1.5 seconds).

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

Please refer to your main controller/gateway manual for how to enter inclusion mode. The device can only be added to the network if the main controller is in inclusion mode.

When the main controller/gateway is configured in inclusion mode, press the link button on the thermostat 3 times in a quick sequence (less than 1.5 seconds).

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

You might also like