OWON - Zigbee Connected Outdoor Temperature Sensor with probe (V2)
The THS-317-ET outdoor connected temperature sensor allows you to precisely measure the temperature of a space (fridge, freezer or other), a material or a liquid (swimming pool or other).
Security guarantees
Shipping Policy
PLEASE NOTE, THIS VERSION IS NOT COMPATIBLE WITH A TUYA GATEWAY (LIDL, WOOX, NOUS etc). CLICK HERE IF YOU WANT THE ZIGBEE TUYA VERSION PROBE.
With the THS-317-ET module you accurately measure the temperature of a space, a material or a liquid.
Thanks to its remote probe, it is possible to measure the temperature of a pipe, such as that of the heating water for example, the temperature of a swimming pool or the temperature of a refrigerator or freezer while positioning the module outside of space.
FUNCTIONS :
- Measure the temperature.
- Remote probe with 2m cable.
- Battery level indication.
- Low energy consumption.
- Compatible with Amazon Echo (with Zigbee technology).
TECHNICAL CHARACTERISTICS :
- Power supply: DC 3V (2X AAA) NOT INCLUDED
- NOT COMPATIBLE TUYA, SMARTLIFE, LIDL
- Display: 2-color LED (Red, Green)
- Temperature measurement: Remote probe - 2m
- Measurement range: -40°C to +200°C Accuracy: ±0.5°C (since January 2024, the THS-317-ET is in V2 and can handle measurements between -40°C to +200°C. The old version V1, no longer commercially available, could only measure between -17°C to +100°C).
- Environment: Temperature: -10 ℃ ~ + 55 ℃
- Humidity: ≤ 85% non-condensing
- Dimensions: 62 (L) × 62 (W) × 15.5 (H) mm
- Connectivity
- ZigBee: 2.4GHz IEEE 802.15.4
- Profile: ZigBee 3.0
- RF Specifications - Frequency: 2.4GHz
- Range (Ext./Int.): 100m / 30m - Internal antenna
Data sheet
- Type
- Sensor
- Functions
- Temperature
- Technology
- ZigBee
- Power Supply
- Battery
- Compatibility
- Amazon Echo
EWeLink (SonOff)
Eedomus
Fibaro HC3
Home Assistant
Jeedom
Zigate
Zigbee2MQTT - Zigbee Version
- Zigbee 3.0
- Known incompatibility
- Lidl / Tuya / Smart Life
Jean-Luc V. published the 21/04/2024 following an order made on 26/03/2024
Tb rien à redire
Gael P. published the 09/04/2024 following an order made on 31/03/2024
Bonne prise en main à voir dans le temps
David B. published the 05/03/2024 following an order made on 28/02/2024
Fonctionne parfaitement avec mon congélateur que est à -30°. Bien compatible Jeedom Atlas Plugin ZigbeeLinker.
Claude C. published the 02/03/2024 following an order made on 26/02/2024
Sonde asssez performante. L'acquisition sur mqtt jeezigbee peut-être fastidieuse. Manque quelques explications pour cette phase. Une fois installée fait bien le travail tant pour la température extérieure que celle du ballon d'eau chaude.
Etienne M. published the 23/02/2024 following an order made on 14/02/2024
Fonctionne sans problème à l'extérieur après avoir installé la partie électronique dans un boîtier étanche en laissant la sonde externe.
Andreas V. published the 23/02/2024 following an order made on 11/01/2024
Sensor sends data only, if temperature changes more than 1°C. That means, that the uncertainty of your knowledge of e.g. room-temperature can not be better than +/- 1°C some time after the last received value.
Peter S. published the 13/02/2024 following an order made on 02/02/2024
Zariadenie plne funkčné s Home Assistant.
Pascal H. published the 06/02/2024 following an order made on 01/02/2024
Excepté une grande lenteur pour faire reconnaître l'un des 2 utilisés, le fonctionnement est stable pour le moment...(2 jours). P.s.: l'écart de mesure reste raisonnable pour usage dans des congélateurs. J'en reprendrai bientôt. Très bonne portée zigbee.
Olivier V. published the 28/01/2024 following an order made on 17/01/2024
Jamais eu autant de difficulté a appairer un device en zigbee. Sachant qu'en plus j'ai été obligé de le faire 2 fois puisqu'il ne répondait plus au bout de quelques heures. Depuis le second apparaige réussi après 1 heure de tentative, je touche du bois car il fonctionne parfaitement. Pourquoi l'avoir conservé.... parce qu'il n'y a pas d'équivalent sur le marché.
It is possible that you have a version with recent firmware that requires modification.
In this case, the command ID must be modified (replace 3::1026::0 by 1::1026::0).