FIBARO - Flood Sensor Z-Wave+ FGFS-101 ZW5
search
  • FIBARO - Flood Sensor Z-Wave+ FGFS-101 ZW5
  • FIBARO - Flood Sensor Z-Wave+ FGFS-101 ZW5
  • FIBARO - Flood Sensor Z-Wave+ FGFS-101 ZW5
  • FIBARO - Flood Sensor Z-Wave+ FGFS-101 ZW5

FIBARO - Flood Sensor Z-Wave+ FGFS-101 ZW5



FGFS-101-ZW5
€93.18 Tax included

FIBARO Flood Sensor is the most beautiful and functional flood sensor ever made.


6 Products available
Quantity

 

Security guarantees

 

Shipping Policy

FIBARO Flood Sensor is the most beautiful and functional flood sensor ever made. Z-Wave compatible FIBARO Flood Sensor will protect your home from water leaks and flood. Flood Sensor design to be placed on a floor or wall.

It rains for a few days and water flooded the basement? Flood Sensor will send you information about the incident as soon as the first drops are detected. From now on, you can always react very quickly to prevent serious damages.

Flood Sensor will help you to configure underfloor heating. The device, put on the flood, sends temperature readings to the central unit. A properly configured system automatically adjusts settings of the heating to the preferences of family members, without putting you at the risk of higher bills.

Small leak unnoticed for a longer time may cause serious damage at your home. Flood Sensor placed under the bath or sink will inform you quickly, even when the smallest amount of water is detected. Now, there is no need to worry about losses caused by leakage.

FEATURES :

  • Plug and Play extremely easy installation without drilling and wiring.
  • May be installed anywhere Flood Sensor contacts extended with a wire
  • Detects water leaks before it became a problem
  • Alerts of a threatening flood, tilt or a rapid temperature change
  • Triggers mobile notification
  • Compatibles with any Z-Wave network controller
  • Battery-powered for up to 2.5 years
  • Possibility to Integrate with any traditional alarm system

TECHNICAL DATAS :

  • Wireless technology: Z-Wave
  • Power: CR123A Battery
  • External Power: 12-24 VDC
  • Output Terminal Voltage: 40V (AC or DC) max.
  • Output Terminal Current: 25mA max.
  • Measure Temperature: -20 to +100°C
  • Dimensions (diameter x height): 72 x 28mm

FGFS-101-ZW5
6 Items

Data sheet

Type
Sensor
Functions
Flood
Temperature
Technology
Z-Wave Plus
Power Supply
12/24VDC
Battery
Compatibility
Eedomus
Fibaro HC3
Fibaro HC3 Lite
Homey
Jeedom
View the trust certificate
  • For further information on the nature of the review controls, as well as the possibility of contacting the author of the review please consult our Transparency Charter.
  • No inducements have been provided for these reviews
  • Reviews are published and kept for a period of five years
  • Reviews can not be modified: If a customer wishes to modify their review then they can do so by contacting Verified Reviews directly to remove the existing review and publish an amended one
  • The reasons for deletion of reviews are available here.

4.6 /5

Based on 14 customer reviews

  • 1
    0
  • 2
    0
  • 3
    2
  • 4
    2
  • 5
    10
Sort reviews by :

Anonymous customer published the 13/02/2021 following an order made on 29/01/2021

5/5

Fonctionne très bien, appairé à une sirène Z-Wave, le système est totalement autonome.

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 05/02/2021 following an order made on 23/01/2021

5/5

Efficace fonctionnel et esthétique, ce n'est pas le moins cher des capteurs mais reste le top, je recommande la marque fibaro, gage de qualité

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 01/02/2021 following an order made on 20/01/2021

5/5

J'avais besoin d'un détecteur pour garder un œil sur des zone sensible, il rempli parfaitement ce rôle et en plus il est très simple à configurer.

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 18/06/2020 following an order made on 30/05/2020

5/5

Concernant le rapport qualité(bien meilleur avec la promotion), le design et l'ergonomie (parfait), et comme d'habitude, il faut voir dans le temps pour la solidité.

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 09/07/2019 following an order made on 09/05/2019

4/5

Tres bon produit, mais les personnes ne connaissant pas le système, le manipule en pensant que c'est un objet perdu ou tombé de son support !

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 18/04/2019 following an order made on 14/03/2019

3/5

Le produit remplit sa fonction, mais après trois semaines, le niveau de batterie est déjà tombé à 75% alors qu'il y a plusieurs appareils Zwave connectés à proximité.

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 09/04/2018 following an order made on 27/03/2018

5/5

parfait et tres simple

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 03/04/2018 following an order made on 19/03/2018

5/5

Fonctionne parfaitement sous Jeedom, facile à inclure et à intégrer

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 17/02/2018 following an order made on 28/01/2018

5/5

Conforme à ma déscription du produit

Did you find this helpful? Yes 0 No 0

Anonymous customer published the 19/12/2017 following an order made on 27/11/2017

3/5

Difficultés de liaison avec la box

Did you find this helpful? Yes 0 No 0

×

Removing the Fibaro Flood Sensor from the Z-Wave network restores all device settings to default.

To remove the device from the Z-Wave network:

1. Open the lid.

2. Place the flood sensor in direct range of your Z-Wave controller.

3. Put your Z-Wave controller in exclusion mode (see controller manual).

4. Quickly press the TMP button three times.

5. Wait for the exclusion process to complete.

6. Successful exclusion will be confirmed by a message on the Z-Wave controller.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. Open the lid.

2. Place the flood sensor in direct range of your Z-Wave controller.

3. Put your Z-Wave controller in include mode (see controller manual).

4. Quickly press the TMP button three times.

5. Wait for the inclusion process to complete.

6. Successful inclusion will be confirmed by the message from the Z-Wave controller.

If the sensor is not included, reset it and repeat the inclusion procedure.

Inclusion in security mode must be carried out up to 2 meters from the controller.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

The FIBARO Flood Detector is equipped with an LED diode, it allows to display the operating modes and alarms of the detector.

The LED indicator also shows the Z-Wave network range and current temperature.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

There is only one way to reset the FIBARO Flood Detector. The reset procedure clears the memory of the device, including all Z-Wave network and master controller information. The reset procedure does not remove the Sensor from the Z-Wave network master controller memory. Before resetting a detector, you must remove it from the Z-Wave network.

1. Check that the detector is powered.

2. Hold down the TMP button.

3. Wait 15-20 seconds for the LED to turn yellow to confirm entry into the 4th submenu.

4. Release the button and press once again.

5. Wait a moment until the LED turns red and an acoustic signal confirms the reset.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

To enable Z-Wave network testing, the device must be added to the Z-Wave controller. The tests can stress the network, so it is recommended to perform the test only in special cases.

Follow the instructions below to test the range of the Z-Wave controller:

1. Press and hold the TMP button until the visual indicator turns purple.

2. Release the TMP button.

3. Briefly press the TMP button again.

4. The visual indicator will show the range of the Z-Wave network.

FLASHING GREEN – The detector is trying to establish direct communication with the main controller

GREEN – The detector is in direct communication with the main controller

FLASHING YELLOW – The detector is trying to establish communication with the main controller via other modules

YELLOW – The detector is in indirect communication with the main controller

FLASHING PURPLE – The detector is communicating with the controller at the limit of the controller's range

RED – The detector cannot connect to the main controller, either directly or through other nodes in the Z-Wave network

5. To exit the Z-Wave range test, short press the TMP button.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

When you navigate in the menus, your position in the MENU is indicated by a color of the LED.

Press and hold the TMP button for at least 3 seconds to enter the MENU.

Each color corresponds to a different MENU level. Press the TMP button to confirm your choice.

WHITE - Confirmation of entry into the MENU

GREEN - Cancel alarm for paired devices

ROSE - Z-Wave Network Range Test

YELLOW - Sensor Reset

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. Advanced Parameter #2 has been changed.

Please set Advanced Setting No. 2 = 3.

2. Advanced Parameter #77 has been changed.

Please change Advanced Parameter No. 77 = 0.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. FIBARO Flood Detector has been reset.

After resetting the FIBARO Flood Detector, it returns to its default settings. You have to start its inclusion to the Z-Wave controller again.

2. The battery of the FIBARO Flood Detector is almost discharged.

The FIBARO Flood Detector must be powered. Check if your battery is effectively discharged by opening the case of your FIBARO Flood Detector. Then close the case and put it back in place.

NOTE: Before using a FIBARO Flood Detector, remember to remove the “I'm ready” tab.

3. The FIBARO Flood Detector is not powered.

The FIBARO Flood Detector must be powered. b) open the case of the device and check that terminals 12 and GND are well connected to the mains, check the power supply. If your FIBARO Flood Detector is powered by a battery, check the battery. Then close the case and put it back in place.

4. The FIBARO Flood Sensor is out of range of the Z-Wave controller.

The FIBARO Flood Detector is out of range of the Z-Wave controller. It must be within direct range of the Z-Wave controller or within range of another node on the Z-Wave mesh network.

5. The FIBARO Flood Detector is damaged

Please contact your dealer to initiate the warranty procedure for your FIBARO Flood Detector.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

Your FIBARO Flood Detector still works as when it was included in the Z-Wave network.

The FIBARO Flood Detector must be powered in the same way as when it was included in the Z-Wave network. If you perform the inclusion while your FIBARO Flood Detector is in battery power mode, it will remain in battery power mode. Conversely, if you perform the inclusion while your FIBARO Flood Detector is in mains mode, it will remain in mains mode.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

The FIBARO Flood Detector allows to control up to 5 standard devices and 5 multi-channel devices for each association group.

Add a maximum of 5 Z-Wave devices to an association group.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

FIBARO Flood Detector has detected a safety fault.

The FIBARO Flood Detector is equipped with a motion/tilt sensor. To dismiss the flood alarm, you must disable the motion sensor. To turn off the motion sensor, you must change Advanced Setting No. 74 = 0.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. The battery is almost discharged.

Open the case of the device, replace the battery with a new one, close the case and replace it in its location.

2. The FIBARO Flood Detector does not report that it has a new battery.

Please wait for FIBARO Flood Detector to wake up or manually wake it up by pressing the TMP button on the device. Then close the case and put it back in place.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. The FIBARO Flood Sensor is not powered.

The FIBARO Flood Sensor must be powered. Please check AC power or battery:

a) open the device case and check the battery,

b) open the case of the device and check that terminals 12 and GND are well connected to the mains, check the power supply,

c) then close the case and put it back in place.

NOTE

Before using your FIBARO Flood Sensor please remove the "I'm ready" tab and remember that all connections must be made by professionals.

2. FIBARO Flood Detector has been reset.

After resetting the FIBARO Flood Sensor, it returns to its default settings. You have to start its inclusion to the Z-Wave controller again.

3. The FIBARO Flood Sensor is out of range of the Z-Wave controller.

The FIBARO Flood Sensor is out of range of the Z-Wave controller. It must be within direct range of the Z-Wave controller or within range of another node on the Z-Wave mesh network.

4. Advanced Parameter #77 has been changed.

Please change Advanced Parameter No. 77 = 0.

5. The FIBARO Flood Detector is damaged.

Please contact your dealer to initiate the warranty procedure for your FIBARO Flood Sensor.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. The FIBARO Flood Sensor is placed too close to a heat source.

The FIBARO Flood Sensor must be placed in an area that is at risk of flooding and with a reference temperature. Avoid locations near a heat source.

2. Advanced Parameter #73 has been changed.

Parameter No. 73 of the FIBARO Flood Sensor allows the compensation of the detected temperature. Check that parameter No. 73 = 0

NOTE

Remember that the temperature on the ground is not the same as in the middle of a room.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

1. The FIBARO Flood Sensor is already included in another Z-Wave controller.

FIBARO Flood Sensor must be deleted using the Z-Wave controller or must be reset as follows:

a) open the cover of the device,

b) press and hold the TMP button until the LED turns yellow,

c) release the button and press again,

d) close the cover and replace the sensor.

2. The FIBARO Flood Sensor is too far from the Z-Wave controller.

The FIBARO Flood Sensor must be within direct range of the Z-Wave controller during the inclusion process.

3. The FIBARO Flood Sensor is not powered.

The FIBARO Flood Sensor must be powered. Please check AC power or battery:

a) open the device case and check the battery,

b) open the case of the device and check that terminals 12 and GND are well connected to the mains, check the power supply,

c) then close the case and put it back in place.

NOTE

Before using your FIBARO Flood Sensor, please remove the "I'm ready" tab and remember that all connections must be made by professionals.

 

4. The FIBARO Flood Sensor has a different frequency (EU, US, or ANZ) than your Z-Wave controller.

The FIBARO Flood Sensor must operate on the same Z-Wave frequency (EU, US, or ANZ) as your Z-Wave controller. Please contact your dealer to exchange it.

5. The FIBARO Flood Sensor is damaged.

Please contact your dealer to initiate the warranty procedure for your FIBARO Flood Sensor.

Does this answer your question?
Yes (0)
No (0)
Sorry about that
How can we improve it?
Submit
Thanks
Your feedback helps improve this answer for everyone.

You might also like