How to include Sunricher scene controller?

Step 1. Make sure the scene controller does not belong to any Z-Wave network. Short press any button, if the LED indicator does not light up, the scene controller does not belong to any network, you can continue step 2. If the LED indicator lights up, it means that the scene controller has already been included in a network, please exclude the scene controller first, then continue with step 2.

Step 2. Put the main controller/gateway into inclusion mode (please refer to your main controller's manual on how to put it into inclusion mode).

Step 3. Press and hold both group 2 buttons (top buttons) for 3 seconds. The LED light will turn on, the scene controller will be in inclusion mode and waiting to be included. After 10 seconds, the LED indicator flashes 6 times quickly to indicate successful inclusion.

The scene controller is a sleeping device. After inclusion, it will not enter sleep mode immediately, and will remain in wake-up state for 30 seconds and wait for data interaction with the gateway. The LED light will stay on, please be patient to wait for the LED light to turn off.